Release 10.1A: OpenEdge Deployment:
Startup Command and Parameter Reference
Before-image Buffers (-bibufs)
Use Before-image Buffers (
-bibufs) to specify the number of before-image buffers. This parameter is useful only when running the Before-image Writer (BIW).
Operating system
and syntax UNIX
Windows-bibufsn Use
with Maximum value Minimum value Single-user default Multi-user default Database Server – 3 – 20
nThe number of before-image buffers.
The BIW continually writes the filled before-image buffers to disk, making the buffers available to other client and server processes. Without a BIW writing the buffers, any gain from increasing the number of buffers is negligible.
For more information on setting this parameter, see OpenEdge Data Management: Database Administration .
|
Copyright © 2005 Progress Software Corporation www.progress.com Voice: (781) 280-4000 Fax: (781) 280-4095 |