Release 10.1A: OpenEdge Deployment:
Startup Command and Parameter Reference


Before-image Buffers (-bibufs)

Use Before-image Buffers (-bibufs) to specify the number of before-image buffers. This parameter is useful only when running the Before-image Writer (BIW).

Operating system
and syntax
UNIX
Windows
-bibufs n
Use
with
Maximum value
Minimum value
Single-user default
Multi-user default
Database Server
3
20

n

The number of before-image buffers.

The BIW continually writes the filled before-image buffers to disk, making the buffers available to other client and server processes. Without a BIW writing the buffers, any gain from increasing the number of buffers is negligible.

For more information on setting this parameter, see OpenEdge Data Management: Database Administration .


Copyright © 2005 Progress Software Corporation
www.progress.com
Voice: (781) 280-4000
Fax: (781) 280-4095